湖南瑞勒装饰工程有限公司

地址:长沙市开福区万家丽路北路一段699号

手机:18163786145

Mail:[email protected]

安装指导
焊条和安装
                                PVC地板施工工艺流程及施工步骤                                
     Installation Direction Procedure  
                             
一、地坪检测  Baseground Condition Test                                 
1.室内温度以及地表温度以15℃为宜,不应在5℃以下及30℃以上施工。宜于施工的相对空气湿度应界于20%-75%之间。                                
Temperature and Humidity:
A. Most optimal temperature inside: around Around 15℃.
B. Workable air humidity range: 20%-75%.                                
2.使用含水率测试仪检测基层的含水率,基层的含水率应百分之三。                                
Moisture content:controlled under 3% tested by moisture content meter.                                
3.基层的强度不应低于混凝土强度C-20的要求。                                
Substrate strength :not lower than C-20 standard of concrete demand.                                
4.基层的表面硬度不低于1.2兆帕。                                
Substrate hardness:not lower than 1.2Mpa.                                
5.基层的不平整度应在2米直尺范围内高低落差小于2-3毫米,否则应采用适合的自流平进行找平。找平层损坏或平整度超过5mm误差,应由基层施工承包商负责承担质量责任。                                
Substrate flatness :level tolerance controlled in 2-3mm in range of 2 square meters,otherwise should be made up by self-leveling.                                
6.原地面基层应平整,不起沙、不掉皮,混凝土、水泥砂浆基层应压光处理。                                
Substrate polishing:should be smooth without sanding,crack;cement and concrete baseground should be polished clean.                                
二、地坪预处理 Substrate Preparation                                 
1.采用地坪打磨机配适当的磨片对地坪进行整体打磨,除去油漆,胶水等残留物,凸起和疏松的地块,有空鼓的地块也必须去除。                                
Dry grinding:to get rid of paint and glue leftover with polishing tools on surface, and also loose cement and crack should be cleared up.                                
2.对地坪进行整体吸尘清洁。                                
Cleaning: dust collection and cleaning                                
3.对于地坪上的裂缝进行修补。                                
Reparing:make up the crack completely. 
                               
                   基础地面施工情况                                
一、瓷砖地面                                 
 Ceramics condition                                
1.清除瓷砖地面上的固化剂,油类、油脂、油漆、灰尘等。                                
Get rid of paint,oil and dust etc on ceramics.                                
2.采用非吸收性界面剂涂刷在瓷砖上,目的是为了封闭自流平表面的细小毛孔和灰尘,使其表面光滑提高粘结剂粘结效果,避免施工结束后地板起鼓及脱胶。                                
Coating the non-absorbing primer on the ceramics to cover the tiny holes and make the glue more adhesive during the construction.                                
二、水泥地面                                  
Cement condition                                
1.清除水泥地面上的固化剂,油类、油脂、油漆、灰尘,打磨。                                
Get rid of paint,oil and dust etc on cement and polishing.                                
2.采用吸收性界面剂涂刷在基础地面上,目的是为了封闭自流平表面的细小毛孔和灰尘,使其表面光滑提高粘结剂粘结效果,避免施工结束后地板起鼓及脱胶。                                
Coating the absorbing primer on the cement to cover the tiny holes and make the glue more adhesive during the construction.                                
三、若有木地板铺在地面                                 
Wooden condition                                
1.检查木地板的状况,将所有木地板块钉牢。                                
Inspect the condition of wooden base , and fix all of them piece by piece.                                
2.将所有木地板上的节或洞用适当的材料填补。                                
Fill in all the gaps among all pieces of wooden flooring.                                
3.在其上铺上一层硬板,胶合板或夹板,厚度至少8mm这些板必须每隔10-15CM用钉钉牢。                                
Laying one layer of 8mm stiff board or laminating sheet above the wooden flooring , and then fix with screws at each 10-15 cm separation.                                 
4.检查木地板底部是否干燥通风。                                
Check the bottom of wooden flooring whether under in air and dry condition .                                
5.所有通风不良的木地板应当除去。                                
Remove all the unqualified sheets .                                

四、旧的乙烯基材料地板 
Resilient flor condition                                 
"1.在安装新的地板胶前,旧的乙烯基地板,亚麻油毯或橡胶地板一般都应拆除,并检查地板底层
以及根据需要对地板层进行处理。"                                
Remove all the old resilient flor before preparation for construction.  
                             
 PVC地板卷材、片材铺设步骤              
铺设片材步骤                                
 Laying procedure for vinyl tiles                                
1.清洁基础地面                                
Cleaning the base ground                                 
2.在基础地面上刷界面剂                                
Coating the primer on the clean base ground                                
3.自流平基础施工                                
Constructing the self-leveling layer, normal thickness is 2-3mm,depends on the level tolerance of base ground, if it's too high, need construct more self-leveling to make it more smooth.                                
4.在铺设之前24小时,将地板从包装箱中取出,并确保地板水平堆放。最低环境温度应不低于10℃。                                
Laying out the vinyl tiles smoothly on the self-leveing ground before laying 24 hours , lowest temperature cannot be lower than 10℃.                                
5.划一条垂直于主要出入口的轴线,划一条与该轴线垂直的直线,并确保两边的块材均匀分布。                                
Lining  one axis vertically towards the exit,and one more straight line vertical to that axis , make sure the materials left averagely on both sides.                                 
6.在一刻钟内在数平方米的底层地面上涂上胶粘剂。胶水晾干时间不够,将形成气泡。胶水晾干时间太长,胶水的粘结效果较差                                
Coating the adhesive uniformly ,pay attention to the drying time to avoid bubbles in too short time or too dry if laying for a long time.                                
7.将每块地板在其位置上压下去,确保粘结处对接紧密。将地板案棋盘状以90°铺设                                
Stress each piece of tiles strongly in right position and connect correctly.                                 
8.手动使地板平整,然后用一个65公斤的地毯滚子滚压,必要时,24小时候后热焊接合处。                                
Pressing the paved tiles ground with 65 kg roller manually , if it's necessary ,heating weld the gaps.     
排版方式参照洁福样册:片材铺设附1,片材铺设附2
                            
铺设卷材步骤                                   
Laying procedure for PVC  rolls flooring                                
1.清洁基础地面                                
Cleaning the base ground                                 
2.在基础地面上刷界面剂                                
Coating the primer on the clean base ground                                
3.自流平基础施工                                
Constructing the self-leveling layer, normal thickness is 2-3mm,depends on the level tolerance of base ground, if it's too high, need construct more self-leveling to make it more smooth.                                
4.在铺设之前24小时,将地板铺展开,并放置在待涂胶的房间内。最低环境温度应不低于15℃。                                
Laying out the rolls in right rooms and open them for 24 hours before installation, lowest temperature should be above 15℃.                                
5.沿着引导铺设第一排,确保卷材按照光线照下来的方向沿纵向铺设。                                
Normally installing the rolls vertically .                                
6.将卷材折叠回至一半位置。                                
Fold back the paved rolls to be half position.                                
"7.用带细齿的刮刀涂刷一层粘稠的丙烯酸胶粘剂。胶水晾干时间不够,将形成气泡。胶水晾干时
间太长,胶水的粘结效果较差"                                
And then coat the adhesive on the self-leveling ground.Drying too short time will lead to bubbles , and too long time will lead to bad sticky.                                
8.手动使地板平整,然后用一个65公斤的地毯滚子滚压,必要时,24小时候后热焊接合处。                                
Press the paved ground with 65kgs roller ,and then heating weld the joints with welding rods.                                 
9.在安装后48小时内,切勿在地板材料上行走。                                
Don't walk on the paved ground in 48 hours after installation.    
排版方式参照洁福样册:卷材铺设附1,卷材铺设附2
                            
抗静电和导静电地板铺设步骤                                
Laying procedure for anti-static/dissipative /conductive PVC flooring                                
抗静电地板   Anti-static flooring                                
1.采用普通的铺设方法,但胶水采用高性能含水量低的丙烯酸粘剂,使地板胶自动具有抗静电性                                
Normal installation method as rolls pvc flooring except for particular adhesive.                                
2.抗静电性并不依赖于铺设方法,也无需铜条。                                
Because the static value is higher ,so don't need copper coin for paving.                                

包含导电胶粘剂和导电底漆的导电地板的铺设步骤                                
Laying procedure for conductive above conductive adhesive and base paint                                
1.在铺设之前24小时,将地板铺展开,并涂上胶水。最低环境温度应不低于15℃。                                
Open the rolls and coat the adhesive for 24 hours before installation,lowest temperature is not lower than 15℃.                                
2.涂上导电底漆,涂上量应当为100-150g/m,让其干燥至少12小时。                                
Coat 100-150g/m of the conductive paint and let it dry for 12 hours at least.                                 
3.卷材:沿着沿轴引导按长度的方向铺展地板胶片,确保卷材按照光线照下来的方向沿纵向铺设。                                
Lay out the flooring along length direction, and make sure it paving vertically.                                
4.片材:划一条垂直于主要出入口的轴线,划另一条与该轴线垂直的直线,并确保两边的块材均匀分布。                                
Lining one axis vertical towards the main exit, and then draw one straight line vertical towards the axis, make sure the materials left on both sides averagely.                                
5.每30平米的面积使用2lm长的铜条作为接地。当房间面积超过30平方米时,将铜条在房间的边界和对角。                                
Use 2 meters copper coin as the ground connect in each 20 square meters                                 
6.用尖齿刮涂上丙烯酸单面导电胶或其他允许的胶水。为了使涂上的胶水均匀适当,应经常更换刮板。                                
Scratch the acrylic acid on single side,to make it coated uniformly, should change the scraper often.
排版方式参照洁福样册:导电粘胶铺设附1,导电粘胶铺设附2-4
                                
在铜条上铺设导电地板的有关步骤                    
Laying procedure for conductive PVC flooring above the copper coin                                
1.在铺设前,地砖应在施工房间铺开至少24小时,以除去材料中存在的应力。最低环境温度应不低于15℃。                                
Open the rolls and coat the adhesive for 24 hours before installation,lowest temperature is not lower than 15℃.                                
2.划一条垂直于主要出入口的轴线,划一条与该轴线垂直的直线,并确保两边的块材均匀分布。                                
Lining one axis vertical towards the main exit, and then draw one straight line vertical towards the axis, make sure the materials left on both sides averagely.                                
3.将地砖分布划好,沿房子四周留一条走道。                                
Lay the flooring well on the self-leveling ground and left one gallery along four sides.                                
4.将铜条分布划好,使其在每块地砖的中心下形成十字形。                                
Lay the copper coin well with cross.                                
5.在中心区涂好胶粘剂(走道不涂)                                
Coat the adhesive except for the gallery.                                
6.铺设铜条,然后铺设地砖,确保地砖和铜条在接合处紧密衔接。确保胶粘剂不会沾污铜条。折起铜条,在走道上涂胶粘剂,然后将铜条放回涂好胶粘剂处。铺设四周的铜条,每隔40或50平方米,应留10厘米宽的铜条以便接地。                                
Pave the copper coin, and then lay PVC flooring , make sure connecting well and avoid the pollution from adhesive. Folding up the copper coin and coat the adhesive on the gallery then lay it back well. Finally, pave the copper coin on four sides and left 10cm empty coin to connect the ground in each 40 or 50 square meters.                                 
7.手动使地板平整,然后用一个65公斤的地毯滚子滚压,必要时,24小时候后热焊接合处。                                
Make the paved flooring smoothly and then use 65kgs roller to press.                                
8.安装24小时候后,在结合处开槽,然后用热焊接合处。                                
Grooving the connecting everywhere after 24 hours and then heating weld the welding rods.                                 
9.在安装后48小时内,切勿在地板材料上行走。                                
Don't walk on the paved ground in 48 hours after installation.